Contains a list of decisions covering Ex Testing and Ex Certification
under the IECEx Scheme
| Decision Sheet No. |
Standard No. |
Clause/Subject |
Issue Date |
DS
2008/005 |
IEC 60079-15:2005 |
Non-Sparking Device |
2008 08 |
|
DS
2008/004 |
IEC 60079-0:2006 |
Acceptance of test data |
2008 06 |
|
DS
2008/003 |
IEC 60079-15 |
Assessment and testing of electronic ballasts |
2008 02 |
|
DS 2008/002 |
IEC 60112 |
Comparative Tracking Index
(Revision of DS 2006/001) |
2008 02 |
|
DS 2008/001 |
IEC 60079-5:2007 |
Apparent conflict between clauses 4.9 and 5.1.5 of IEC
60079-5:2007 |
2008 01 |
|
DS
2006/009 |
|
Assessment
of an OEM Service facility |
2006 12 |
|
DS
2006/008 |
lEC 60079-11:1999
lEC 60079-11:200x Ed. 5 |
The
requirements for the use of capacitors for
coupling between Intrinsically Safe and Non-Intrinsically
Safe circuits
|
2006 12 |
|
DS
2006/007 |
IEC
60079-0 |
Use
of non-aqueous organic salt lithium (lithium-Ion)
cells |
2006 07 |
|
DS
2006/006 |
IEC
60079-11 |
Method of test for electrochemical cells |
2006 07 |
|
TC 31 /Publication
/
I-SH 01 |
IEC 60079-1 :2001
Ed.4
|
Electrical
Apparatus for Explosive Gas Atmospheres –
Part 1: Flameproof enclosures "d"
|
2007 02 |
|
TC 31 /Publication/
I-SH 01
|
IEC 60079-1 :2003
Ed.5 |
Electrical
Apparatus for Explosive Gas Atmospheres –
Part 1: Flameproof enclosures "d" |
2007 02 |
|
DS 2006/004
and
DS 2006/005
|
|
Status:
Withdrawn
As a result of the publication of the IEC Interpretation
Sheets, available above,
the decision was taken
during the ExTAG Meeting, Denver 2007, to withdraw
DS 2006/004 and
DS 2006/005.
Documents
available in Archives |
Withdrawn
2007 11 15 |
|
DS 2006/003
|
IEC
60079-11 |
Galvanically
separating components |
2006
03 |
|
DS
2006/002 |
|
Ex
equipment where the equipment includes unspecified IECEx
certified components |
2006
02 |
|
DS
2006/001 |
IEC
60112 |
Requirement
for insulating material to meet a certain Comparative
Tracking Index (CTI).
(Revised
refer DS 2008/002) |
2006
01 |
|
DS 2004/006 |
|
ExTAG Decision Sheets /
Procedures for use of components on end products not covered
by an ExTR |
2004 11 |
|
DS 2004/005 |
IEC 61241-0:2004
IEC 61214.1.1:1999
IEC 60079-0:2004
IEC 60079-0:2000 |
ExTAG Decision Sheets /
Non-metallic parts of enclosures |
2004 11 |
|
DS 2004/004 |
lEC 60079 11:1999 02 |
ExTAG Decision Sheets /
Segregation distances where earthed metal separates IS from
Non IS circuits |
2004 11 |
|
DS 2004/003 |
IEC 60079-11 |
ExTAG Decision Sheets / Use
of temperature coefficient for ambient temperatures above 40°C |
2004 11 |
|
DS 2004/002 |
IEC 60079-11: 1999 |
ExTAG Decision Sheets /
Electrochemical cells |
2004 11 |
|
DS 2004/001 |
|
ExTAG Decision Sheets / ExTAG
Recommendation Sheets Additional source of information related
to the application of Ex-Standards |
2004 08 |
|
DS 2003/003 |
IEC 60079-11 |
Assessment of infallible
safety shunt assemblies |
2003 10 08 |
|
DS 2003/002 |
|
ExTAG decisions and
recommendations: Proposal for a procedure to generate, discuss
and finalise them. |
2003 11 |
|
DS 2003/001 |
IEC 60079-11 |
Limitation of RF power
|
2003 05 21 |
| DS 2002/006 |
IEC 60079 11: 1999 02 |
Clause: 7.1
Rating of components |
2002 10 21 |
| DS 2002/005 |
lEC 60079 11:1999 02 |
Clause: 6.4, 7.11, 7.4
Separate voltage sources |
2002 10 21 |
| DS 2002/004 |
IEC 60079 11: 1999 02 |
Clause: 7.4.2,10.9.3
Electrolyte leakage from cells and batteries |
2002 10 21 |
| DS 2002/003 |
IEC 60079 11: 1999 02 |
Clause: 7.11, 7.4.8
Rating of components for battery chargeable equipment |
2002 10 21 |
|
DS 2002/002A |
IEC 61779 1: 1998 04 |
Clause: 3.5
Diffusion Gas Sensing HeadsThis Decision Sheet was revised
to take into account changes within the new edition of the
Standard. |
2008 03 31 |
|
DS 2002/001A |
IEC 60079-11:1999-02 |
Clauses:
5.4, 7.1, 7.4
Electrochemical sensors
This Decision Sheet
was revised (2007-09-25) to take into account editorial
changes |
2007 09 25 |